The steels or rsj s rolled steel joists are often built into one or both walls to give added stability to the roof structure.
Flat roof joist detail.
A cavity closer should be provided to the top of the walls to prevent fire spread and to stop damp air entering the roof space.
Minimum r value of exterior ci determined by total r value of insulated assembly see also.
1 enter joist details 1 1 span and joist spacing.
Joists are placed on edge spaced at 400 600mm centres supported by external and internal load bearing walls.
Cantilever nails may be used to attach backer block if length of nail is sufficient to allow clinching.
I joists are comprised of top and bottom flanges which resist bending united with webs which provide outstanding shear resistance.
Where a new flat roof abuts an existing external wall the joists can be hung on metal joist hangers which are fixed to a horizontal timber plate wall bolted to the wall.
This detail for cmu installation only.
Usually 400 450 or 600mm but any value can be used up to 610mm max.
In the warm flat roof construction there is insulation packed into every possible space where air can flow.
There is no need for bearing posts under the ridge board which is nonstructural.
On a basic level flat roof construction comes in the form of roofing timbers or joists as they are more commonly known or steels that are laid across two uprights walls in most cases.
The full version allows any size.
Detail for attachment to metal panel siding or fascia.
Downspout strap detail 1 4 dia.
Continuous insulation on top of sheathing exterior ci with fiber fill in joist cavity this is how to detail an unvented roof assembly for flat and low slope roofs.
Nail to backer block and joist with 2 rows of 10d nails 6 o c.
Trada and approved document part a give guidance on sizes of joists for flat roofs relating to spans and loading.
In a typical roof framed with dimension lumber the rafters rest on the exterior wall top plate at the lower end and bear against a ridge board at the top.
The flange material is typically laminated veneer lumber lvl or solid sawn lumber and the web is made with plywood or osb.
Continuous ceiling joists or collar ties span from rafter to rafter.
The major difference between the warm flat roof and the cold flat roof has to do with the air flow between the roofing timbers known as joists that help to hold up the roof.
The construction of the flat roof is similar to that of the timber upper floor.
Figure 3 i joist cantilever detail for balconies 1 1 2 x l4 minimum 4 maximum where l is length l of cantilever 2 x 8 min.
X 5 8 bolt brass alum.